Actions to be taken in case of an oil/chemical spillage and pool fire:
Prompt initiation of the Emergency Shutdown (ESD) limits the amount of liquid spilled and, due to the fish plate, restricts overflow of cargo overboard.
Restrict sources of ignition to prevent vapour ignition.
Gently spread foam over the pool fire to smother it and restrict spreading.
Never direct jets of water onto burning liquid, as this causes a violent increase in flame and spreads the fire.
When contained in drip trays, liquid may spill onto the deck; avoid water jets in such cases.
Wear full protective clothing and use water spray protection.